SCORPIO version 2.0
Structure-Calorimetry Of Reported Protein Interactions Online
Home
Browse proteins
Browse ligands
Browse ITC data
Browse structures
Browse citations
ITC
Browse
ITC data
Instruments
Interaction types
Buffers
Comments
Comment definitions
ΔC
p
Browse ITC comments
<
>
ITC comment
ITC comment defintion
DeltaG (-62.76) less than -60.00. It is difficult to interpred ITC data if DeltaG is less than -60.00 as the sigmoidal curve becomes too sharp. This can be overcome by performing displacement experiments.
DUBIOUS_DATA
DeltaH (8.37) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (-6.28) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (0.84) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (8.79) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (-5.02) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
Affinity (1250.0000) greater than 313.4408. It is difficult to interpred ITC data if Affinity is greater than 313.4408 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaG (-16.70) greater than -20.00. It is difficult to interpred ITC data if DeltaG is greater than -20.00 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaG (-19.90) greater than -20.00. It is difficult to interpred ITC data if DeltaG is greater than -20.00 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaG (-63.60) less than -60.00. It is difficult to interpred ITC data if DeltaG is less than -60.00 as the sigmoidal curve becomes too sharp. This can be overcome by performing displacement experiments.
DUBIOUS_DATA
DeltaG (-17.53) greater than -20.00. It is difficult to interpred ITC data if DeltaG is greater than -20.00 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaG (-76.57) less than -60.00. It is difficult to interpred ITC data if DeltaG is less than -60.00 as the sigmoidal curve becomes too sharp. This can be overcome by performing displacement experiments.
DUBIOUS_DATA
DeltaH (-8.37) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (2.23) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (2.40) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (9.75) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (-6.44) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (-6.65) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
Affinity (333.3333) greater than 313.4408. It is difficult to interpred ITC data if Affinity is greater than 313.4408 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
Affinity (578.0347) greater than 313.4408. It is difficult to interpred ITC data if Affinity is greater than 313.4408 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
1
2
3
4
5