DeltaG (-17.24) greater than -20.00. It is difficult to interpred ITC data if DeltaG is greater than -20.00 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
Affinity (884.9558) greater than 313.4408. It is difficult to interpred ITC data if Affinity is greater than 313.4408 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaG (-16.84) greater than -20.00. It is difficult to interpred ITC data if DeltaG is greater than -20.00 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
Affinity (1305.4830) greater than 313.4408. It is difficult to interpred ITC data if Affinity is greater than 313.4408 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaG (-16.46) greater than -20.00. It is difficult to interpred ITC data if DeltaG is greater than -20.00 as the sigmoidal curve becomes too shallow.
DUBIOUS_DATA
DeltaH (7.11) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (5.36) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (9.00) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (-7.53) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (7.95) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaG (-60.25) less than -60.00. It is difficult to interpred ITC data if DeltaG is less than -60.00 as the sigmoidal curve becomes too sharp. This can be overcome by performing displacement experiments.
DUBIOUS_DATA
DeltaG (-62.34) less than -60.00. It is difficult to interpred ITC data if DeltaG is less than -60.00 as the sigmoidal curve becomes too sharp. This can be overcome by performing displacement experiments.
DUBIOUS_DATA
DeltaH (9.20) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaG (-61.50) less than -60.00. It is difficult to interpred ITC data if DeltaG is less than -60.00 as the sigmoidal curve becomes too sharp. This can be overcome by performing displacement experiments.
DUBIOUS_DATA
DeltaH (-2.93) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.
DUBIOUS_DATA
DeltaH (-4.60) in range 10.00 to -10.00. It is difficult to interpret ITC data as DeltaH approaches 0.